Views:

Summary



The database and the Catalog are synonymous. The database is responsible for keeping track of data on media and your Enterprise configuration. For example, job cataloging, Enterprise login, catalog condenses, and everything you configure through the DPX management console.

Details



The database and the Catalog are synonymous. The database is responsible for keeping track of data on media and your Enterprise configuration. For example, job cataloging, Enterprise login, catalog condenses, and everything you configure through the DPX management console.
 
Message NumberNameExplanationAction
2982ERR_DB_PREV_CONDENSE_NOT_COMPLETEDThis message signals an error indicating that the previous condense has not finished. 
2983ERR_DB_NO_BASE_BACKUP_FOUNDThis message signals that an incremental or differential backup could not find a base backup to reference. 
2984ERR_DB_FAIL_TO_FIX_CATALOG_FILESThis message signals an error augmenting catalog files.The main catalog table could not be found, call technical support and prepare for a catalog restore.
2985ERR_DB_FAIL_TO_GET_TABLE_DESCRIPTORThis message signals an error retrieving a catalog table descriptor. 
2986ERR_DB_FAIL_TO_GET_FILE_DESCRIPTORThis message signals an error retrieving a catalog file descriptor.If this is a UNIX master server, make sure that your operating system isn't running out of open file descriptors. A 'man' on the command 'ulimit' should describe how to address this problem.
2987ERR_DB_INVALID_FILE_RECORDThis message signals a file record is invalid. 
2988ERR_DB_INVALID_TABLE_DESCRIPTORThis message signals a table record is invalid. 
2989ERR_DB_INVALID_FILE_DESCRIPTORThis message signals that the file descriptor is invalid. A catalog table has been corrupted, call Catalogic Software Technical Support for assistance in possible table reconstruction or catalog restore.
2990ERR_DB_FAIL_TO_RELEASE_FILEDThis message signals that the file descriptor could not be released. 
2991ERR_DB_STRING_TOKEN_RESERVEDA reserved message token was used in the command line interface DPX. 
2992ERR_DB_INVALID_SELDIR_LISTThe selection list for this job is invalid. This message is returned only by the command line interface.Check that number of selection items is less than the maximum of 500. Define additional jobs if necessary. Check that the total length of the selection list is less than the maximum of 15 KB. Define additional jobs as necessary.
2993ERR_DB_INVALID_JOBID_STRThe job identification string failed validation. 
2994ERR_DB_INVALID_PARTITION_STRThe partition string was not in the correct format. 
2995ERR_DB_INVALID_OPTIONSThe global options string failed validation. 
2996ERR_DB_INVALID_FILE_PATHThe file path is not in the correct format. 
2997ERR_DB_GET_CATALOG_FILE_RECORDIn Condense, the attempt to get a file record failed. 
2998ERR_DB_GET_CATALOG_CHUNK_RECORDIn Condense, the attempt to get a catalog chunk record failed. 
2999ERR_DB_EXCEED_DEVICE_SERVER_MAX_LIMITThe number of entries in the device server table exceeds the maximum. 
3000ERR_DB_RESERVED_CHARACTERThis message signals a reserved character error. 
3001ERR_DB_INVALID_USER_NAMEThe user logged into DPX with an invalid name. 
3002ERR_DB_COMMENT_TOO_LONGA comment exceeded the maximum string length. 
3003ERR_DB_UNKNOWN_TOKENThe database encountered an unknown token. 
3004ERR_DB_WRONG_TOKENThe database encountered an incorrect token. 
3005ERR_DB_INSERT_RECORDThe database encountered a record insertion error. 
3006ERR_DB_FLUSH_FILEThe database encountered an error flushing a file.Make sure that hard disk containing the catalog has not run out of space.
3007ERR_DB_FLUSH_HEADERAn attempt to flush the header of a database record failed.Make sure that hard disk containing the catalog has not run out of space.
3008ERR_DB_INVALID_RECORDA database record was found to be corrupt. 
3009ERR_DB_RECORD_NOT_FOUNDThe database record could not be found. 
3010ERR_DB_NO_BUFFER_FOR_NEW_RECORDAn attempt to insert a new database record failed.(1) Increase the RAM on the operating system.
(2) Reduce the buffer for sschunk and ssfile, call Catalogic Software Technical Support for assistance.
3011ERR_DB_CREATE_FILEThis message signals that the database could not create a file.Make sure that hard disk containing the catalog has not run out of space.
3012ERR_DB_CREATE_DIRECTORYThis message signals that the database could not create a directory.Make sure that hard disk containing the catalog has not run out of space or inodes.
3013ERR_DB_FILE_DOESNOT_EXISTAn attempt to access a nonexistent database file was made. 
3014ERR_DB_DIRECTORY_DOESNOT_EXISTAn attempt to access a nonexistent database directory was made. 
3015ERR_DB_MEMORY_ALLOCATEA request to allocate memory for the database failed. 
3016ERR_DB_SEND_MESSAGEThe send message operation failed. 
3017ERR_DB_RECEIVE_MESSAGEThe receive message operation failed. 
3018ERR_DB_WRITE_FILEThe program could not write the info file. 
3019ERR_DB_OPEN_FILEThe requested device file could not be opened.For Tape Libraries, check that the IDs for the robotic arm drivers are installed and are specified correctly.
3020ERR_DB_FILE_SEEKAn error was encountered while executing a file seek operation in the central message logger. 
3021ERR_DB_FILE_READThis message signals an error reading a file in a database routine. 
3022ERR_DB_FILE_DELETEThis message signals an error deleting a file in a database routine. 
3023ERR_DB_DIRECTORY_REMOVEThis message signals an error removing a directory in a database routine. 
3024ERR_DB_FILE_RENAMEThis message signals an error renaming a file in a database routine. 
3025ERR_DB_RECORD_DOESNOT_EXISTA database record was not found. 
3026ERR_DB_NO_MORE_FILEThere are no more files in the directory. 
3027ERR_DB_INITIALIZEIn Condense, there was an initialization error. 
3028ERR_DB_BAD_INIFILEIn Condense, there was a bad initialization file. 
3029ERR_DB_MISSING_DIRECTORYThe database directory could not be found. 
3030ERR_DB_WRONG_NAMEAn invalid name for the database was specified. 
3031ERR_DB_MISSING_FILENAMENo database name was given. 
3032ERR_DB_DUPLICATE_TABLEDuplicate table entries were found. 
3033ERR_DB_CLOSE_TABLEThe database table could not be closed. 
3034ERR_DB_FILE_OUT_OF_SYNCThe database file is out of sync with the catalog. 
3035ERR_DB_CONDENSE_RECOVERThis message signals a recovery error during the catalog condense. 
3036ERR_DB_FILE_MISSING_CAN_RECOVERA database message error was detected, but the problem is repairable. 
3037ERR_DB_FILE_MISSING_CANNOT_RECOVERA database message error was detected, and the problem is unrepairable. . 
3038ERR_DB_INVALID_DIRECTORYAn invalid database directory was specified. 
3039ERR_DB_INVALID_CHUNKThe database chunk is nonexistent. 
3040ERR_DB_NO_MORE_CHUNKThere are no more database chunks to read or write. 
3041ERR_DB_CHUNK_NOT_FOUNDThe requested chunk was not located in the database. 
3042ERR_DB_FILE_NOT_FOUNDThe file that was located in the directory listing could not be found. 
3043ERR_DB_RESET_BUFFERThis message signals an error resetting the database buffer. 
3044ERR_DB_UNKNOWN_TABLEThe table requested is not among the types recognized. 
3045ERR_DB_FILE_INVALID_FORMATThe database file is in an invalid format. 
3046ERR_DB_APPEND_FILEThis message signals an error appending to the database file. 
3047ERR_INCORRECT_PWThe login password was invalid. 
3048ERR_USER_NOT_LOGGED_INThe user is not logged in as an authorized user. . 
3049ERR_USER_UNKNOWNThe user id is unknown. 
3050ERR_USER_UNAUTHORIZEDThe user privilege classes do not allow the requested operation. 
3051ERR_DB_MSG_INVALID_STRINGThe string generated fails the cyclic redundancy check. 
3052ERR_DB_NO_PRIVILEGEThis error signals no privileges for the operation. 
3053ERR_DB_LOCKEDThis message signals that the database is write-locked. 
3054ERR_DB_DISABLEDThe database is disabled. The only operation allowed is 'enable.'. 
3055ERR_DB_BUFFEREDThe request to sync the database cannot be honored because the database is locked. 
3056ERR_DB_PREFERENCE_DATA_INITIALIZEAn error occurred while initializing the user preference data. 
3057ERR_INVALID_FILENAME_FORMATOn a Netware system, an invalid filename was encountered. 
3058ERR_ACCESSING_PARENT_RECThe attempt to access the record for the parent directory failed. 
3059ERR_OBTAINING_LOCKThis message signals a database lock error. 
3060ERR_ANOTHER_COPY_ACTIVEThis message signals another database is active.