Views:

Summary

While restoring data from SnapVault backup through Instant Access (IA) map functionality, the following error displays: rc=23008 Failed to create iSCSI Target Portal." To resolve this issue, ensure that the required interface is enabled "

 

Symptoms

The DPX management console displays the following dialog box while attempting to perform an Instant Access map.

 

 

Resolution

Even during an IA map failure, the backup to the storage system continues to succeed. However, the IA map may fail with rc=23008 because the IA map operation refers to an iSCSI enabled (physical or logical) network interface.

In this scenario, the logical virtual network interface 0 (vif0) is disabled for iSCSI.

Validate available iSCSI interfaces on the storage system by opening a telnet session to the storage system and running the command:

iscsi interface show

The result may display as follows:

Ensure that the required interface is enabled.

In the above example, interface vif0 is disabled and you can enable it by running the command:

iscsi interface enable vif0